LGP-21 orders
LGP-30 differences

operand
operand
Z 0, 100 Stop 0 Stop
Z 0200, 0300 no operation
not available
Z 4, 8, 16, 32 Skip if any BS n off
not available
-Z 0, 4, 8, 16, 32 Skip if any BS n off .OR. oflo off
not available
B m Bring
same as LGP-21
Y m Store address
same as LGP-21
R m Set return address
same as LGP-21
I device Input 6 bits 0 Input 6 bits
-I device Input 4 bits 0 Input 4 bits
I 6200 Shift left 6
not available
-I 6200 Shift left 4
not available
D m Divide
same as LGP-21
N m Multiply: save right
same as LGP-21
M m Multiply: save left
same as LGP-21
P 0 Start reader
same as LGP-21
P device Print 6 bits of ACC char Print 6 bits of order
-P device Print 4 bits of ACC char Print 4 bits of order
E n Extract
same as LGP-21
U m Uncond. transfer
same as LGP-21
T m Transfer if -ACC
same as LGP-21
-T m Transfer if -ACC .OR. TC
same as LGP-21
H m Hold
same as LGP-21
C m Store and clear ACC
same as LGP-21
A m Add
same as LGP-21
S m Subtract
same as LGP-21
All works here unless otherwise specified are copyright 2026 by Tom Jennings. Permission is granted for personal use with no remuneration. Corporations or any organization or their agents, employees, consultants or other relationships human or otherwise, expressly prohibited without written permission.